Global Blood Resources LLC  

 

For Physicians

 
 

Methodology

The Hemobag® process consists of 3 simple steps:

Step 1 (After surgery)

Fill at surgical field via the extracorporeal circuits arterial line connected to the Hemobag® (alternatively you can connect the aortic cannula into a 1/4 inch line like the unused sucker or vent line and fill down below at the level of the pump once it's taken out of the roller head and the other end connected to the top of the Hemobag®), then chase forward the circuit's blood volume with crystalloid displacement.

Step 2

Apply the Hemobag® to the closed TS3 Tubing Set's "Recovery Loop circuit" for hemoconcentration via a spare roller pump not in use. Concentrate down to a fine, rich, autologous whole blood product with harmful wastes and excess water removed but all cellular components saved from being discarded.

Step 3

 With the lines clamped and capped, the Hemobag® is now ready for labeling and end-product infusion.

Hemobag® Methodology

Click on thumbnails to enlarge | Also see video below

Hemobag TS3 tubing

Global Blood Resources LLC is pleased to offer a short video (~2 min. 30 secs.) that shows how the Hemobag® works in the operative setting. Turn speakers on and double click arrow.